Choose the thermal actuator that matches your manifold valve, the wiring centre’s actuator output, and the valve position you need when power is off. Start with Danfoss TWA-A for an RA connection, Caleffi 6563 for the listed Caleffi manifolds, or Danfoss TWA-K for the specified M30 × 1.5 valves. Danfoss RA option, Caleffi 6563, Danfoss valve fit.
24 V and 230 V compatibility matrix
Use the row that fits your valve and control requirements, then match the wiring centre’s actuator output to the part’s full supply rating, including any specified AC frequency. For a Danfoss actuator, use its linked part page to confirm the AC frequency range before ordering.
| Valve or manifold | Select this version for | 24 V part | 230 V part |
|---|---|---|---|
| Danfoss RA connection | TWA-A, normally closed, no end switch | 088H3110, 24 V AC | 088H3112, 230 V AC |
| Heimeier, MNG or Oventrop M30 × 1.5 valve | TWA-K, normally closed, no end switch | 088H3140, 24 V AC/DC | 088H3142, 230 V AC |
| Heimeier, MNG or Oventrop M30 × 1.5 valve | TWA-K, normally open, no end switch | 088H3141, 24 V AC/DC | 088H3143, 230 V AC |
| Caleffi 662 or 663 manifold | 6563, normally closed, with manual opening and auxiliary microswitch | 656314, 24 V AC/DC | 656312, 230 V AC |
| Valve confirmed to fit ENGO’s M30 × 1.5 actuator | ENGO E30NC, normally closed, with first-open feature for installation | E30NC-24, 24 V AC/DC | E30NC-230, 230 V AC at 50 Hz |
Four checks before ordering
- Read the actuator output rating. Match the wiring centre’s actuator output to the exact part’s full supply rating, including voltage, AC or DC, and any specified AC frequency. For example, the Danfoss Icon wiring centre 088U1041 specifies a 230 V AC output. Danfoss 088U1041 specifications. The ENGO E30NC-230 is rated for 230 V AC at 50 Hz. ENGO E30NC-230 specifications.
- Identify the manifold or valve model. Look up the exact series in the actuator’s compatibility list. For a TWA-K on a valve outside Danfoss’s named matches, confirm the valve closing dimensions and the shape of the valve top even if the thread is M30 × 1.5. Caleffi compatibility list, Danfoss fit requirements.
- Match the position with power off. With a Danfoss TWA actuator unpowered, the valve is closed for normally closed (NC) and open for normally open (NO). Check which type your controller supports before choosing a row. Danfoss valve functions.
- Check whether the controls use an end switch. If the system uses an actuator’s end switch to signal a pump relay or heat source, choose a version with that contact. Check the switch’s contact rating separately from the actuator supply rating. Uponor end-switch example, Caleffi switch and supply ratings.
Example replacement for a Caleffi 663
Suppose your Caleffi 663 uses a 24 V AC actuator output and calls for a normally closed actuator with an auxiliary microswitch. The matching 6563 part is 656314, which Caleffi lists for the 663 series with a 24 V AC/DC supply. Its 230 V AC counterpart is 656312. Caleffi part numbers and specifications.
Evidence and limits. The Danfoss TWA and Icon, Caleffi 6563, ENGO E30NC, and Uponor four-wire product pages were checked on November 26, 2026. No installation or bench testing was performed.