<?xml version="1.0" encoding="UTF-8"?><rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Hydronic Zone Guide: Underfloor Heating Zone Panels</title><description>Plain guides to underfloor heating zone panels and replacements, built from published official documentation.</description><link>https://hydroniczoneguide.com/</link><language>en</language><atom:link href="https://hydroniczoneguide.com/rss.xml" rel="self" type="application/rss+xml"/><item><title>neoHub, Smatrix Pulse and Relay Boards in Home Assistant</title><link>https://hydroniczoneguide.com/posts/connecting-heatmiser-neohub-uponor-smatrix-pulse-relay-boards/</link><guid isPermaLink="true">https://hydroniczoneguide.com/posts/connecting-heatmiser-neohub-uponor-smatrix-pulse-relay-boards/</guid><description>Pair a Heatmiser neoHub, send setpoint commands to Uponor Smatrix Pulse through Google, and add a Shelly relay board to Home Assistant.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Pair a Heatmiser neoHub Gen 2 or Gen 3 through HomeKit Device, and add a networked Shelly relay board through the Shelly integration. For Uponor Smatrix Pulse rooms that already respond to Google Assistant, try sending the same setpoint command from Home Assistant through Google Assistant SDK. &lt;a href=&quot;https://faq.heatmiser.com/hc/en-us/articles/360001693080-How-do-I-know-if-my-neoHub-supports-HomeKit&quot;&gt;Heatmiser compatibility&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/homekit_controller&quot;&gt;HomeKit Device&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/shelly/&quot;&gt;Shelly integration&lt;/a&gt; · &lt;a href=&quot;https://www.uponor.com/en-en/products/room-temperature-controls/uponor-smatrix-pulse/uponor-smatrix-pulse-faqs&quot;&gt;Uponor FAQ&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/google_assistant_sdk&quot;&gt;Google Assistant SDK&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Pair the Heatmiser neoHub&lt;/h2&gt;
&lt;p&gt;Check the back of the hub for the HomeKit pairing code. Heatmiser lists Gen 2 and Gen 3 as compatible with HomeKit. Gen 1 lacks HomeKit support. The Home Assistant integration named &lt;strong&gt;Heatmiser&lt;/strong&gt; is for DT, DT-E, PRT and PRT-E thermostats. &lt;a href=&quot;https://faq.heatmiser.com/hc/en-us/articles/360001693080-How-do-I-know-if-my-neoHub-supports-HomeKit&quot;&gt;Heatmiser compatibility&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/heatmiser/&quot;&gt;Heatmiser integration&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Set up the Neo system in the neoApp first. Put the neoHub and Home Assistant on the same local network. &lt;a href=&quot;https://www.heatmiser.com/homekit-on-neo-faq/&quot;&gt;Heatmiser setup&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/integrations/homekit_controller#home-assistant-cannot-discover-my-device&quot;&gt;HomeKit Device discovery&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;If the hub is already paired to Apple Home, remove it from that app to free it for pairing. If the old pairing prevents discovery, open your location in the neoApp and select &lt;strong&gt;Settings → HomeKit → cog icon → Reset HomeKit Configuration&lt;/strong&gt;. Heatmiser says this reset preserves neoStat pairings. &lt;a href=&quot;https://www.home-assistant.io/integrations/homekit_controller&quot;&gt;HomeKit Device pairing&lt;/a&gt; · &lt;a href=&quot;https://www.heatmiser.com/homekit-on-neo-faq/&quot;&gt;Heatmiser troubleshooting&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;In Home Assistant, go to &lt;strong&gt;Settings → Devices &amp;amp; services&lt;/strong&gt;. Select &lt;strong&gt;Configure&lt;/strong&gt; on the discovered &lt;strong&gt;HomeKit Device&lt;/strong&gt;, enter the code from the hub, assign it to a room and select &lt;strong&gt;Finish&lt;/strong&gt;. &lt;a href=&quot;https://www.home-assistant.io/integrations/homekit_controller&quot;&gt;HomeKit Device pairing&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;If a zone is missing after pairing, compare its thermostat model with Heatmiser’s HomeKit accessory list. &lt;a href=&quot;https://faq.heatmiser.com/hc/en-us/articles/360001723179-Which-products-work-with-HomeKit&quot;&gt;Heatmiser accessory compatibility&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Keep the neoHub connected to the Heatmiser Cloud. Heatmiser says the hub needs that connection to remain operational even though HomeKit traffic travels over the local network. &lt;a href=&quot;https://www.heatmiser.com/homekit-on-neo-faq/&quot;&gt;Heatmiser HomeKit FAQ&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Send a setpoint to Uponor Smatrix Pulse&lt;/h2&gt;
&lt;p&gt;Uponor documents room temperature control through Google Home. The SDK action sends a command to Google Assistant. Check the resulting setpoint at the target room before using the action in an automation. &lt;a href=&quot;https://www.uponor.com/en-en/products/room-temperature-controls/uponor-smatrix-pulse&quot;&gt;Uponor room temperature controls&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/actions/google_assistant_sdk.send_text_command/&quot;&gt;Text command action&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;With Smatrix Pulse set up in its app and connected to the Uponor cloud, open Google Home. Tap &lt;strong&gt;Add → Device → Add a different way&lt;/strong&gt;, search for Uponor, select its app and follow the linking prompts. If you recently updated to Smatrix Pulse 2, Uponor directs you to unlink and relink in Google Home. &lt;a href=&quot;https://www.uponor.com/en-en/products/room-temperature-controls/uponor-smatrix-pulse/uponor-smatrix-pulse-faqs&quot;&gt;Uponor FAQ&lt;/a&gt; · &lt;a href=&quot;https://support.google.com/googlehome/answer/9159862?hl=en-CA&quot;&gt;Google Home linking&lt;/a&gt; · &lt;a href=&quot;https://www.uponor.com/en-en/products/room-temperature-controls/uponor-smatrix-pulse-two&quot;&gt;Uponor Pulse 2 update&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Try a Google Assistant temperature command for one linked room. Use the device name as Google knows it and check that the intended room&apos;s target temperature changes. &lt;a href=&quot;https://support.google.com/googlehome/answer/7207759/control-google-nest-or-home-devices-by-voice?hl=en-GB&quot;&gt;Google thermostat commands&lt;/a&gt; · &lt;a href=&quot;https://www.home-assistant.io/actions/google_assistant_sdk.send_text_command/&quot;&gt;Home Assistant command targeting&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Enable &lt;strong&gt;Google Assistant API&lt;/strong&gt; in your Google Cloud project. If you need credentials, follow the SDK guide to create a &lt;strong&gt;Web application&lt;/strong&gt; OAuth client with &lt;code&gt;https://my.home-assistant.io/redirect/oauth&lt;/code&gt; as the authorized redirect URI. In Home Assistant, go to &lt;strong&gt;Settings → Devices &amp;amp; services → Add Integration → Google Assistant SDK&lt;/strong&gt;. Enter the client ID and client secret and authorize with the Google account that controls the linked room. &lt;a href=&quot;https://www.home-assistant.io/integrations/google_assistant_sdk&quot;&gt;Google Assistant SDK setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;Open &lt;strong&gt;Settings → Tools → Actions&lt;/strong&gt; and choose &lt;strong&gt;Google Assistant SDK: Send text command&lt;/strong&gt;. Enter the command that worked in step 2 and select &lt;strong&gt;Perform action&lt;/strong&gt;. Confirm the new setpoint in the Uponor app or on a thermostat that displays its target temperature. &lt;a href=&quot;https://www.home-assistant.io/actions/google_assistant_sdk.send_text_command/&quot;&gt;Text command action&lt;/a&gt; · &lt;a href=&quot;https://www.uponor.com/en-en/products/room-temperature-controls/uponor-smatrix-pulse&quot;&gt;Uponor app controls&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Add a networked relay board&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Once the relay is installed and on the network, open &lt;strong&gt;Settings → Devices &amp;amp; services&lt;/strong&gt; and look for the discovered Shelly device. If it is absent, select &lt;strong&gt;Add Integration → Shelly&lt;/strong&gt; and enter its hostname or IP address in &lt;strong&gt;Host&lt;/strong&gt;. &lt;a href=&quot;https://www.home-assistant.io/integrations/shelly/&quot;&gt;Shelly integration setup&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;If the Shelly device has more than one relay, find the sub-device for each relay channel. Shelly relays appear as &lt;code&gt;switch&lt;/code&gt; entities by default. On a Shelly Pro 3, compare the channel name in Home Assistant with the output name in the device&apos;s web interface. &lt;a href=&quot;https://www.home-assistant.io/integrations/shelly/&quot;&gt;Shelly entity naming and defaults&lt;/a&gt; · &lt;a href=&quot;https://www.shelly.com/blogs/documentation/shelly-pro-3-web-interface-guide&quot;&gt;Shelly Pro 3 web interface&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;Use a dry contact for Smatrix Comfort/ECO&lt;/h3&gt;
&lt;p&gt;Uponor&apos;s European manuals for the Base Pulse X-245 and Wave Pulse X-265 document a dry-contact &lt;strong&gt;GPI&lt;/strong&gt; for switching the system between Comfort and ECO. This function requires the R-208 communication module. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Physical installation follows the manufacturer&apos;s manual and local rules. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Set the GPI function to &lt;strong&gt;Comfort/ECO&lt;/strong&gt; in &lt;strong&gt;Installer settings&lt;/strong&gt; during initial configuration or in &lt;strong&gt;System settings&lt;/strong&gt;. The system supports a single external Comfort/ECO switch, which disables &lt;strong&gt;Forced ECO&lt;/strong&gt; in the Smatrix Pulse app. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;After commissioning, operate the relay using its Home Assistant switch. Check for a mode change on a thermostat that displays Comfort/ECO. &lt;a href=&quot;https://www.home-assistant.io/integrations/shelly/&quot;&gt;Shelly switch entities&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt; · &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; The Home Assistant 2026.11.3 docs and the linked Heatmiser, Uponor, Google and Shelly documentation were checked on November 27, 2026. The steps were not run on hardware.&lt;/p&gt;
</content:encoded><category>home-assistant</category><category>heatmiser</category><category>uponor</category><category>relays</category><author>Hydronic Zone Guide Editorial</author></item><item><title>Hydronic Manifold End Switches and Zone Controls</title><link>https://hydroniczoneguide.com/posts/wiring-hydronic-manifold-end-switches-boilers-circulator-pumps/</link><guid isPermaLink="true">https://hydroniczoneguide.com/posts/wiring-hydronic-manifold-end-switches-boilers-circulator-pumps/</guid><description>Compare hydronic manifold actuator end switches, zone panel inputs and outputs, and demand controls for circulators, boilers, and heat pumps.</description><pubDate>Fri, 27 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;An isolated end switch in a hydronic manifold actuator closes when the valve is fully open. A zone control can use that signal to start a shared distribution circulator and request heat. In a buffer-tank-controlled system, the heat pump responds to tank temperature. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-single-circulator-distribution-systems&quot;&gt;Caleffi manifold controls&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-us/blog/design-details-air-water-heat-pump&quot;&gt;Caleffi heat-pump design&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Actuator types and dry contacts&lt;/h2&gt;
&lt;p&gt;An isolated end switch is a dry contact. It opens or closes a control circuit independently of the actuator’s power circuit and supplies no voltage of its own. Caleffi’s 6563 thermo-electric actuator is available with this option. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi end-switch configurations&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-us/blog/4-zoning-thermostatic-valves-i36&quot;&gt;Caleffi 6563 actuator example&lt;/a&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Two-wire valve.&lt;/strong&gt; Caleffi’s example has power leads only, with no end switch. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi Figure 3-17&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Three-wire valve.&lt;/strong&gt; The end switch in Caleffi’s example shares the motor’s power source. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi Figure 3-17&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Four-wire valve.&lt;/strong&gt; Caleffi’s example has an end switch electrically isolated from the motor circuit. The switch is intended for low-voltage signaling. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi Figure 3-17&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Zone panel inputs and outputs&lt;/h2&gt;
&lt;p&gt;Caleffi’s ZVR106 accepts calls from zone thermostats, powers the corresponding zone valve, and signals the heat source. Taco’s cold-start boiler example uses an on/off demand input on the boiler control and a circulator managed by the Taco control. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi Figure 3-19&lt;/a&gt;, &lt;a href=&quot;https://www.tacocomfort.com/knowledge-base/electronic-controls/&quot;&gt;Taco cold-start boiler example&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;Installation follows the equipment manufacturer’s manual and local rules.&lt;/p&gt;
&lt;h2&gt;Heat-pump demand controls&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;External on/off control.&lt;/strong&gt; Arctic’s installer training specifies a 5 V DC remote on/off input designed for a dry-contact relay. Its separate mode input, when enabled, selects heating with the contact open and cooling with it closed. &lt;a href=&quot;https://www.arcticheatpumps.com/hvac-industry-contact-submission.html&quot;&gt;Arctic installer training&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Buffer tank control.&lt;/strong&gt; A buffer tank is typically needed when retrofitting an extensively zoned hydronic system with a heat pump that has a fixed-speed compressor. With tank-temperature control, the heat pump can keep charging the tank after the room thermostat is satisfied. A hydronic heat pump also has a minimum flow requirement. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/design-details-air-water-heat-pump&quot;&gt;Caleffi buffer tank controls&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-us/blog/4-other-considerations-when-evaluating-existing-systems&quot;&gt;Caleffi minimum flow guidance&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Heat pump with a backup boiler.&lt;/strong&gt; In Caleffi’s two-stage example, a controller reads the tank sensor and calls the heat pump first. It calls the boiler when the tank temperature drops to the second-stage threshold. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/design-details-air-water-heat-pump&quot;&gt;Caleffi two-stage setpoint control&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;What happens during a thermostat call&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Valve.&lt;/strong&gt; In Caleffi’s zone panel example, a thermostat call energizes the associated valve actuator. A thermal actuator can take time to reach its fully open position. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi Figure 3-19&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-us/blog/4-zoning-thermostatic-valves-i36&quot;&gt;Caleffi actuator response&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Circulator and boiler.&lt;/strong&gt; In a system that uses the end switch as its enable signal, the switch closes at full opening and signals the circulator and boiler to operate. In Caleffi’s boiler example, if the water temperature is within the controller’s differential below the high limit, the burner waits for the water to cool through that differential. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-single-circulator-distribution-systems&quot;&gt;Caleffi manifold controls&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-troubleshooting-process&quot;&gt;Caleffi boiler operating example&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Tank-controlled heat pump.&lt;/strong&gt; The tank temperature governs heat-pump demand. In Caleffi’s two-stage example, the tank controller uses a setpoint and differential for each stage. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/design-details-air-water-heat-pump&quot;&gt;Caleffi two-stage setpoint control&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; This guide draws on Caleffi’s idronics documentation, including issue 36 for the ZVR106 and 6563-series examples, Taco’s electronic controls knowledge base, and Arctic’s installer training. The equipment behavior was not verified by hands-on testing.&lt;/p&gt;
</content:encoded><category>hydronic-manifolds</category><category>end-switches</category><category>zone-controls</category><category>circulators</category><category>heat-pumps</category><author>Hydronic Zone Guide Editorial</author></item><item><title>Best 24V and 230V Manifold Thermal Actuators</title><link>https://hydroniczoneguide.com/posts/best-24v-230v-manifold-thermal-actuators-compatibility-matrix/</link><guid isPermaLink="true">https://hydroniczoneguide.com/posts/best-24v-230v-manifold-thermal-actuators-compatibility-matrix/</guid><description>Compare 24V and 230V underfloor heating actuators by manifold fit, output voltage, valve position and end switch, then find the right part number.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Choose the thermal actuator that matches your manifold valve, the wiring centre’s actuator output, and the valve position you need when power is off. Start with Danfoss TWA-A for an RA connection, Caleffi 6563 for the listed Caleffi manifolds, or Danfoss TWA-K for the specified M30 × 1.5 valves. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3110&quot;&gt;Danfoss RA option&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;Caleffi 6563&lt;/a&gt;, &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa&quot;&gt;Danfoss valve fit&lt;/a&gt;.&lt;/p&gt;
&lt;h2&gt;24 V and 230 V compatibility matrix&lt;/h2&gt;
&lt;p&gt;Use the row that fits your valve and control requirements, then match the wiring centre’s actuator output to the part’s full supply rating, including any specified AC frequency. For a Danfoss actuator, use its linked part page to confirm the AC frequency range before ordering.&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Valve or manifold&lt;/th&gt;
&lt;th&gt;Select this version for&lt;/th&gt;
&lt;th&gt;24 V part&lt;/th&gt;
&lt;th&gt;230 V part&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Danfoss RA connection&lt;/td&gt;
&lt;td&gt;TWA-A, normally closed, no end switch&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3110&quot;&gt;088H3110&lt;/a&gt;, 24 V AC&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/en-ro/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3112&quot;&gt;088H3112&lt;/a&gt;, 230 V AC&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Heimeier, MNG or Oventrop M30 × 1.5 valve&lt;/td&gt;
&lt;td&gt;TWA-K, normally closed, no end switch&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3140&quot;&gt;088H3140&lt;/a&gt;, 24 V AC/DC&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3142&quot;&gt;088H3142&lt;/a&gt;, 230 V AC&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Heimeier, MNG or Oventrop M30 × 1.5 valve&lt;/td&gt;
&lt;td&gt;TWA-K, normally open, no end switch&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3141&quot;&gt;088H3141&lt;/a&gt;, 24 V AC/DC&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa/p/088H3143&quot;&gt;088H3143&lt;/a&gt;, 230 V AC&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Caleffi 662 or 663 manifold&lt;/td&gt;
&lt;td&gt;6563, normally closed, with manual opening and auxiliary microswitch&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;656314&lt;/a&gt;, 24 V AC/DC&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;656312&lt;/a&gt;, 230 V AC&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Valve confirmed to fit ENGO’s M30 × 1.5 actuator&lt;/td&gt;
&lt;td&gt;ENGO E30NC, normally closed, with first-open feature for installation&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://engocontrols.com/en/produkt/e30nc-24/&quot;&gt;E30NC-24&lt;/a&gt;, 24 V AC/DC&lt;/td&gt;
&lt;td&gt;&lt;a href=&quot;https://engocontrols.com/en/produkt/e30nc-230-3/&quot;&gt;E30NC-230&lt;/a&gt;, 230 V AC at 50 Hz&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Four checks before ordering&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Read the actuator output rating.&lt;/strong&gt; Match the wiring centre’s actuator output to the exact part’s full supply rating, including voltage, AC or DC, and any specified AC frequency. For example, the Danfoss Icon wiring centre 088U1041 specifies a 230 V AC output. &lt;a href=&quot;https://designcenter.danfoss.com/en-gb/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/room-controls-230v/icon-wiring-centers/danfoss-icon-230v-wiring-center/p/088U1041&quot;&gt;Danfoss 088U1041 specifications&lt;/a&gt;. The ENGO E30NC-230 is rated for 230 V AC at 50 Hz. &lt;a href=&quot;https://engocontrols.com/en/produkt/e30nc-230-3/&quot;&gt;ENGO E30NC-230 specifications&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Identify the manifold or valve model.&lt;/strong&gt; Look up the exact series in the actuator’s compatibility list. For a TWA-K on a valve outside Danfoss’s named matches, confirm the valve closing dimensions and the shape of the valve top even if the thread is M30 × 1.5. &lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;Caleffi compatibility list&lt;/a&gt;, &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa&quot;&gt;Danfoss fit requirements&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Match the position with power off.&lt;/strong&gt; With a Danfoss TWA actuator unpowered, the valve is closed for normally closed (NC) and open for normally open (NO). Check which type your controller supports before choosing a row. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/actuators/thermal-actuators/twa&quot;&gt;Danfoss valve functions&lt;/a&gt;.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Check whether the controls use an end switch.&lt;/strong&gt; If the system uses an actuator’s end switch to signal a pump relay or heat source, choose a version with that contact. Check the switch’s contact rating separately from the actuator supply rating. &lt;a href=&quot;https://www.uponor.com/en-us/products/controls/four-wire-thermal-actuators&quot;&gt;Uponor end-switch example&lt;/a&gt;, &lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;Caleffi switch and supply ratings&lt;/a&gt;.&lt;/li&gt;
&lt;/ol&gt;
&lt;h2&gt;Example replacement for a Caleffi 663&lt;/h2&gt;
&lt;p&gt;Suppose your Caleffi 663 uses a 24 V AC actuator output and calls for a normally closed actuator with an auxiliary microswitch. The matching 6563 part is &lt;strong&gt;656314&lt;/strong&gt;, which Caleffi lists for the 663 series with a 24 V AC/DC supply. Its 230 V AC counterpart is &lt;strong&gt;656312&lt;/strong&gt;. &lt;a href=&quot;https://www.caleffi.com/en-int/thermo-electric-actuator-with-manual-opening-and-position-indicator--6563-caleffi-656312&quot;&gt;Caleffi part numbers and specifications&lt;/a&gt;.&lt;/p&gt;
&lt;p&gt;&lt;em&gt;Evidence and limits.&lt;/em&gt; The Danfoss TWA and Icon, Caleffi 6563, ENGO E30NC, and Uponor four-wire product pages were checked on November 26, 2026. No installation or bench testing was performed.&lt;/p&gt;
</content:encoded><category>thermal-actuators</category><category>manifolds</category><category>underfloor-heating</category><category>zone-controls</category><author>Hydronic Zone Guide Editorial</author></item><item><title>Danfoss Icon2 vs Uponor Smatrix Pulse vs Heatmiser UH8 (UFH)</title><link>https://hydroniczoneguide.com/posts/danfoss-icon2-uponor-smatrix-pulse-heatmiser-uh8-hydronic/</link><guid isPermaLink="true">https://hydroniczoneguide.com/posts/danfoss-icon2-uponor-smatrix-pulse-heatmiser-uh8-hydronic/</guid><description>Compare Danfoss Icon2, Uponor Smatrix Pulse and Heatmiser UH8 by actuator voltage, thermostat type, zone capacity and boiler control.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Shortlist &lt;strong&gt;Danfoss Icon2&lt;/strong&gt; if you want to mix wired and wireless room thermostats on one controller. Choose &lt;strong&gt;Uponor Smatrix Base Pulse&lt;/strong&gt; for wired Uponor thermostats or &lt;strong&gt;Wave Pulse&lt;/strong&gt; for wireless ones, with 24 V AC Uponor actuators connected directly to either room controller. Choose &lt;strong&gt;Heatmiser UH8&lt;/strong&gt; for up to eight heating zones with wired 230 V thermostats and 230 V actuators. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller?tab=products&quot;&gt;Danfoss Icon2&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Uponor Base Pulse&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Uponor Wave Pulse&lt;/a&gt;, &lt;a href=&quot;https://heatmisershop.co.uk/heatmiser-uh8-8-zone-230v-underfloor-heating-wiring-centre/&quot;&gt;Heatmiser UH8&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Match the thermostats and actuators&lt;/h2&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Controller&lt;/th&gt;
&lt;th&gt;Thermostat connection&lt;/th&gt;
&lt;th&gt;Manifold actuator compatibility&lt;/th&gt;
&lt;th&gt;Capacity before expansion&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Danfoss Icon2 Basic&lt;/td&gt;
&lt;td&gt;Wired 24 V or wireless. Both can be used together.&lt;/td&gt;
&lt;td&gt;230 V on 088U2102. 24 V on 088U2105. Both controllers have a 230 V supply rating.&lt;/td&gt;
&lt;td&gt;15 channels on either model. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller?tab=products&quot;&gt;Icon2 overview&lt;/a&gt;, &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller/p/088U2102&quot;&gt;088U2102 specs&lt;/a&gt;, &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller/p/088U2105&quot;&gt;088U2105 specs&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Uponor Smatrix Base Pulse X-245&lt;/td&gt;
&lt;td&gt;Wired Uponor Smatrix Base bus&lt;/td&gt;
&lt;td&gt;Uponor 24 V AC actuators only at the room controller&lt;/td&gt;
&lt;td&gt;Up to six channels and eight actuators. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Uponor Smatrix Wave Pulse X-265&lt;/td&gt;
&lt;td&gt;Wireless Uponor Smatrix Wave thermostats&lt;/td&gt;
&lt;td&gt;Uponor 24 V AC actuators only at the room controller&lt;/td&gt;
&lt;td&gt;Up to six channels and eight actuators. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Heatmiser UH8&lt;/td&gt;
&lt;td&gt;Wired 230 V room thermostats&lt;/td&gt;
&lt;td&gt;230 V actuator outputs&lt;/td&gt;
&lt;td&gt;Up to eight heating zones. &lt;a href=&quot;https://heatmisershop.co.uk/heatmiser-uh8-8-zone-230v-underfloor-heating-wiring-centre/&quot;&gt;UH8 specifications&lt;/a&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Count rooms and manifold actuators separately&lt;/h2&gt;
&lt;p&gt;List each thermostat-controlled room and mark which manifold loops it serves. If a kitchen has two loops with an actuator on each, record one thermostat and two actuators. Uponor&apos;s manuals allow one thermostat to control more than one channel. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Retrofit with seven wired 230 V thermostats and seven compatible 230 V actuators.&lt;/strong&gt; The UH8 fits those counts and voltages. Icon2 Basic 088U2102 matches the actuator voltage but uses 24 V wired thermostat communication. Both Smatrix Pulse room controllers accept only Uponor 24 V AC actuators at their actuator outputs. &lt;a href=&quot;https://heatmisershop.co.uk/heatmiser-uh8-8-zone-230v-underfloor-heating-wiring-centre/&quot;&gt;UH8 specifications&lt;/a&gt;, &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller/p/088U2102&quot;&gt;088U2102 specs&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;New Uponor build with seven room thermostats and eight actuators.&lt;/strong&gt; Seven thermostats exceed the six-thermostat limit of either unexpanded controller, even though each supports up to eight actuators. Add the M-242 to Base Pulse or the M-262 to Wave Pulse. Each adds six thermostat channels and six actuator outputs. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Check the pump and boiler connections&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Danfoss Icon2&lt;/strong&gt; provides a 230 V circulation pump output and a heat-demand output that can use a volt-free relay. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller?tab=products&quot;&gt;Icon2 overview&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Uponor Base and Wave Pulse&lt;/strong&gt; can use separate dry contacts for the pump and boiler on the master room controller. The pump contact switches an external supply. The boiler connection requires a dry-contact sensing input at the boiler. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Heatmiser UH8&lt;/strong&gt; provides a 230 V output for the underfloor pump and valve and a volt-free boiler connection. With the slide switch set to radiator mode, a call from zone 8 opens the radiator valve. A radiator-only call does not activate the underfloor pump or valve. The radiator valve&apos;s end switch calls the boiler when wired to enable it. &lt;a href=&quot;https://heatmisershop.co.uk/heatmiser-uh8-8-zone-230v-underfloor-heating-wiring-centre/&quot;&gt;UH8 specifications&lt;/a&gt;, &lt;a href=&quot;https://faq.heatmiser.com/hc/en-us/articles/360001852359-How-do-radiator-zones-on-the-Heatmiser-wiring-centres-enable-the-boiler&quot;&gt;Heatmiser radiator-zone guide&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Allow for app hardware&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Danfoss Icon2&lt;/strong&gt; requires an Ally Gateway or compatible Zigbee gateway for smart-home integration. &lt;a href=&quot;https://designcenter.danfoss.com/products/climate-solutions-for-heating/hydronic-floor-heating/room-controls/danfoss-icon2/icon2-main-controllers/danfoss-icon2-main-controller?tab=products&quot;&gt;Icon2 overview&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Uponor Smatrix Pulse&lt;/strong&gt; uses the R-208 communication module for the app. Remote access uses Uponor cloud services. &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Base_PULSE/Uponor_Smatrix_Base_PULSE_en-GB.html&quot;&gt;Base Pulse manual&lt;/a&gt;, &lt;a href=&quot;https://smatrixpulse-support.uponor.com/IOM_Wave_PULSE/Uponor_Smatrix_Wave_PULSE_en-GB.html&quot;&gt;Wave Pulse manual&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Heatmiser with neoStat V2&lt;/strong&gt; uses the neoHub for neoApp access. The hub communicates with the thermostat. &lt;a href=&quot;https://faq.heatmiser.com/hc/en-us/articles/14321747709724-Do-neoStats-need-to-be-connected-to-a-wiring-centre-to-connect-to-the-neoHub&quot;&gt;Heatmiser neoHub support&lt;/a&gt;, &lt;a href=&quot;https://www.heatmiser.com/neo-app-android-phone-user-guide-faq/&quot;&gt;Heatmiser neoApp guide&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;h2&gt;Evidence and limits&lt;/h2&gt;
&lt;p&gt;The Danfoss Icon2 Basic 088U2102 and 088U2105 specifications, Uponor&apos;s UK X-245 and X-265 installation manuals, and documentation for the wired Heatmiser UH8 were checked on 26 November 2026. No installations or hardware tests were performed.&lt;/p&gt;
</content:encoded><category>underfloor-heating</category><category>zone-controllers</category><category>thermostats</category><category>manifold-actuators</category><author>Hydronic Zone Guide Editorial</author></item><item><title>Taco ZVC404 vs. SR Switching Relays for Hydronic Zoning</title><link>https://hydroniczoneguide.com/posts/taco-zvc404-sr-switching-relays-zone-valve-circulator/</link><guid isPermaLink="true">https://hydroniczoneguide.com/posts/taco-zvc404-sr-switching-relays-zone-valve-circulator/</guid><description>Choose a Taco ZVC404 or SR switching relay by identifying what controls flow in each zone. Check valve wire count, pump voltage, and hot water priority.</description><pubDate>Thu, 26 Nov 2026 00:00:00 GMT</pubDate><content:encoded>&lt;p&gt;Choose a &lt;strong&gt;Taco ZVC zone valve control&lt;/strong&gt; when motorized valves open the heating zones and a shared circulator moves water through them. Consider the &lt;strong&gt;ZVC404&lt;/strong&gt; if the model documentation confirms it supports the number of zones you need. Choose a &lt;strong&gt;Taco SR switching relay&lt;/strong&gt; when each zone has a dedicated circulator that starts on a call for heat. &lt;a href=&quot;https://www.tacocomfort.com/product/zone-valve-controls/&quot;&gt;Taco zone valve controls&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/enhanced-switching-relays/&quot;&gt;Taco switching relays&lt;/a&gt; · &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Valve zoning layout&lt;/a&gt; · &lt;a href=&quot;https://www.caleffi.com/en-us/blog/2-zoning-circulators-i36&quot;&gt;Circulator zoning layout&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Match the panel to the piping&lt;/h2&gt;
&lt;p&gt;Find what controls flow on each space-heating branch. A system with motorized zone valves can also have a separate boiler circulator, so check what serves each branch before you count pumps. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi valve zoning layouts, figures 3-1a and 3-1b&lt;/a&gt;&lt;/p&gt;
&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;What you find on the heating branches&lt;/th&gt;
&lt;th&gt;What happens on a call for heat&lt;/th&gt;
&lt;th&gt;Panel family&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;A motorized valve on each branch and one circulator serving those branches&lt;/td&gt;
&lt;td&gt;The calling zone&apos;s valve opens. The shared circulator supplies the active branches.&lt;/td&gt;
&lt;td&gt;ZVC zone valve control&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;A dedicated circulator on each branch&lt;/td&gt;
&lt;td&gt;The calling zone&apos;s circulator starts.&lt;/td&gt;
&lt;td&gt;SR switching relay&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;For example, four thermostats that each open a valve on piping served by a shared circulator point to a ZVC. Four thermostats that each start their own zone circulator point to an SR. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi valve zoning&lt;/a&gt; · &lt;a href=&quot;https://www.caleffi.com/en-us/blog/2-zoning-circulators-i36&quot;&gt;Caleffi circulator zoning&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Compare the exact model numbers&lt;/h2&gt;
&lt;p&gt;For Taco&apos;s Next Generation line, look up &lt;strong&gt;ZVC404-5&lt;/strong&gt; under Zone Valve Controls and &lt;strong&gt;SR504-5&lt;/strong&gt; under Switching Relays. Taco lists support for 2-, 3- and 4-wire zone valves and up to three pumps through pump end switches on the ZVC line. The SR line lists a switchable primary circulator output. Both lines list switchable priority. &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-zone-valve-controls-5/&quot;&gt;Taco Next Generation ZVC&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-switching-relays-5/&quot;&gt;Taco Next Generation SR&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Check these items before ordering&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Model and zone count.&lt;/strong&gt; Copy the full model number from the old panel, including any suffix. List the independent space-heating calls and any indirect hot water call. Consult the candidate model&apos;s instruction sheet to check the zone count and priority. &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-zone-valve-controls-5/&quot;&gt;Taco ZVC model documents&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-switching-relays-5/&quot;&gt;Taco SR model documents&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Connected loads.&lt;/strong&gt; For a ZVC, record each valve&apos;s model, wire count and whether it has an end switch. For an SR, record the circulator voltage. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/3-zoning-motorized-valves-i36&quot;&gt;Caleffi valve electrical details&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-zone-valve-controls-5/&quot;&gt;Taco ZVC submittal and instructions&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-switching-relays-5/&quot;&gt;Taco SR catalog and instructions&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Hot water priority.&lt;/strong&gt; If an indirect tank has priority, its call can temporarily pause the space-heating zones. Identify what serves the tank and check the exact model&apos;s instruction sheet for priority. &lt;a href=&quot;https://www.caleffi.com/en-us/blog/2-zoning-circulators-i36&quot;&gt;Caleffi circulator zoning and priority&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-zone-valve-controls-5/&quot;&gt;Taco ZVC model documents&lt;/a&gt; · &lt;a href=&quot;https://www.tacocomfort.com/product/nex-gen-switching-relays-5/&quot;&gt;Taco SR model documents&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;strong&gt;Evidence and limits.&lt;/strong&gt; This comparison is based on Taco&apos;s ZVC404 and SR product documentation, including the Next Generation &lt;code&gt;-5&lt;/code&gt; series, and Caleffi&apos;s &lt;em&gt;Zoning with Motorized Valves (i36)&lt;/em&gt; and &lt;em&gt;Zoning with Circulators (i36)&lt;/em&gt;. The checks were not performed on installed equipment.&lt;/p&gt;
</content:encoded><category>taco</category><category>zone valves</category><category>circulators</category><category>boiler controls</category><author>Hydronic Zone Guide Editorial</author></item></channel></rss>